2B TECHNOLOGIES
  • Home
  • About
  • Applications
    • Ambient Air
    • Ozone Disinfection >
      • Ozone the Destroyer
    • Industrial Ozone
    • Education
    • AQ Sensors
    • Application Notes
  • Products
    • AQSync Air Quality Monitoring Station
    • Ozone >
      • Ambient Ozone Monitors >
        • Model 106-L
        • Model 202 Ozone Monitor
        • Model 205 Ozone Monitor
        • Model 211 Scrubberless Ozone Monitor
        • Model 211-G Ozone Monitor
        • POM, Personal Ozone Monitor
        • Model 306 Ozone Cal Source
      • Industrial Ozone Monitors >
        • Model 106 Series Ozone Monitors
        • Model-106 Series OEM Ozone Monitors
        • Model 106-L
        • Model 106-M
        • Model 106-MH
        • Model 106-H
        • Model 108-L
        • Model UV-106-W Aqueous Ozone Monitor
        • Model 306 Ozone Cal Source
    • NOx >
      • Model 405 nm NOx Monitor
      • Model 714 NO2/NO/O3 Calibration Source
    • Black Carbon
    • Mercury
    • Instrument/Sensor Packages >
      • AQ Sensors vs Instruments
      • Personal Air Monitor (PAM)
      • AQLite Air Monitoring Packages
    • Calibrators >
      • Model 714 NO2/NO/O3 Calibration Source
      • Model 306 Ozone Cal Source
    • Product Catalog
  • Data Portal
    • Data Portal V2
  • Downloads
  • Quote
  • Parts Online
  • Contact
  • Distributors
  • Tech Support
  • Options and Custom Builds
  • Calibrations
  • Rentals
  • Videos
  • Our Team
  • R & D
  • Citations
  • Customer Feedback
  • Ozone Decision Tree
  • Ozone Units Converter
  • DewLine™
  • Ozone Generator Calculations
  • 2B Buzz Newsletter
  • News Archive

Ozone Monitor Models 106-L, 106-M, 106-MH and 106-H
For Industrial Ozone Applications

Picture
For industrial ozone applications, 2B Tech offers the Model 106-L, 106-M, 106-MH and 106-H Ozone Monitors, where L, M, MH and H refer to Low (0-100 ppm), Medium (0-1,000 ppm)06-, Medium-High (0-10,000 ppm) and High (0-20 wt%) ozone concentrations, respectively. These instruments have different optical path lengths in order to accommodate an extremely wide range of ozone concentrations, spanning more than eight orders of magnitude. Additionally, the Model 106-H was designed with a flow-through path that can be pressurized to up to 50 psi for in-line measurements with ozone generators. All four models are available in either a standard enclosure or Industrial enclosure.  Configurations for multi-channel sampling are available for Models 106-L, 106-M, and 106-MH.

The Model 106 series was designed as an "ozone monitor on a board" in which nearly all of the components are mounted directly to the printed circuit board. Thus, the Model 106 may be purchased without the enclosure for OEM applications. See: Model OEM-106.

The Model 106-L is designed for ambient low measurements down to very low ppb levels and has been designated by the EPA as a Federal Equivalent Method (FEM) for monitoring for compliance with the US Clean Air Act:  EQOA–0914–218.

Our video describes the different models and configurations for our Model 106-Series Ozone Monitors, and could help determine which model is best for a particular application.  Click here or scroll down on this page to view the video.

Specifications for Different Optical Benches

Model Range Resolution Precision & Accuracy
106-L
0-100 ppm
0.0001 ppm (0.1 ppb)
Higher of 0.0015 ppm (1.5 ppb) or 2% of reading
106-M
0-1,000 ppm
0.01 ppm
Higher of 0.01 ppm or 2% of reading
106-MH
0-10,000 ppm (0-1 vol%)
0.1 ppm
Higher of 0.05 ppm or 2% of reading
106-H
0-20 wt% O2 or Air
0-14 vol%
0.01 wt%
0.01 vol%
Higher of 0.01 wt% or 2% of reading

General Specifications

Measurement Principle UV Absorption at 254 nm
Measurement Interval 2 s
Data Averaging Options 2 s, 10 s, 1 min, 5 min, 1 hr
Flow Rate ~1 Liter/min; Up to 20 L/min for Model 106-H
Data Storage 32,736 lines (10 s avg. = 3.7 days; 5 min avg = 113 days)
Choice of Units ppb, pphm, ppm, µg m-3, mg m-3 (for Models 106-L and 106-M)
ppm, mg m-3 (for Model 106-MH)
vol%, wt% air, wt% O2, g/m3, g/Nm3 (for Model 106-H)
Data Outputs USB, RS232, 0-2.5 V Analog, 4-20 mA, LCD Display
Power Requirements 100-240 V AC, 50/60 Hz
11-28 V DC, nominally 500 mA at 12 V DC, 6 watt for Models 106-L, M, and MH
11-28 V DC, nominally 325 mA at 12 V DC, 3.9 watt for Model 106-H
Size (standard enclosure) 3.6 x 7.9 x 9.4 inches (9 x 20 x 24 cm)
Weight (standard and OEM) 4.2 lb (1.9 kg) for Model 106-L; 2.8 lb (1.3 kg) for OEM-106-L
3.9 lb (1.8 kg) for Models 106-M, -MH; 2.5 lb (1.1 kg) for OEM-106-M, -MH
4.4 lb (2.0 kg) for Model 106-H; 2.9 lb (1.3 kg) for OEM-106-H
Size (Industrial enclosure) 16 x 14 x 9.3 inches (40.7 x 35.7 x 23.6 cm) H x W x D
Weight (Industrial enclosure) ~14 lb (6.4 kg) depending on model and multichannel options


Features

  • Measurement based on UV absorption
  • Low power consumption; can be battery operated (optional lithium-ion battery)
  • Internal data logger with real-time clock
  • ​2-s measurement interval
  • On-board microprocessor with interactive menus includes data averaging options of 10 s, 1 m, 5 m and 1 hr
  • USB and RS-232 output of time/date, O3 concentration, internal temperature and pressure
  • Analog output (0-2.5 V and 4-20 mA) of ozone concentration in user selected units
  • Two 2-level relays for control purposes (e.g., control of ozone source or turn warning light on and off); Four 2-level relays in Industrial enclosure models and in the 3-channel and 6-channel optional configurations
  • Long-life pump (15,000 hr) for Models 106-L, 106-M and 106-MH
  • Bluetooth option for wireless data transmission
  • Optional configurations for 3-channel or 6-channel air sampling for Models 106-L, 106-M, and 106-MH

For more details about each instrument, follow the links below:
Model 106-L
Model 106-M
Model 106-MH
Model 106-H
Download Model 106 Series Brochure
Request a Quote

Confused about which ozone monitor best suits your application?
  • Decision Tree: This will help you decide which ozone monitor is best for your application.
  • Comparison: See a table that compares the specifications of all of our ozone monitors.
  • Videos: These describe the Model 106-Series, 202, and 205 Ozone Monitors.
  • Applications: The most suitable ozone monitors for different applications are discussed here.
Our Tech Note #001 compares the specifications of our Models 106-L, 202, 205, 211 and POM with other high precision ozone monitors (Thermo, Teledyne-API and Ecotech).

  • Home
  • About
  • Applications
    • Ambient Air
    • Ozone Disinfection >
      • Ozone the Destroyer
    • Industrial Ozone
    • Education
    • AQ Sensors
    • Application Notes
  • Products
    • AQSync Air Quality Monitoring Station
    • Ozone >
      • Ambient Ozone Monitors >
        • Model 106-L
        • Model 202 Ozone Monitor
        • Model 205 Ozone Monitor
        • Model 211 Scrubberless Ozone Monitor
        • Model 211-G Ozone Monitor
        • POM, Personal Ozone Monitor
        • Model 306 Ozone Cal Source
      • Industrial Ozone Monitors >
        • Model 106 Series Ozone Monitors
        • Model-106 Series OEM Ozone Monitors
        • Model 106-L
        • Model 106-M
        • Model 106-MH
        • Model 106-H
        • Model 108-L
        • Model UV-106-W Aqueous Ozone Monitor
        • Model 306 Ozone Cal Source
    • NOx >
      • Model 405 nm NOx Monitor
      • Model 714 NO2/NO/O3 Calibration Source
    • Black Carbon
    • Mercury
    • Instrument/Sensor Packages >
      • AQ Sensors vs Instruments
      • Personal Air Monitor (PAM)
      • AQLite Air Monitoring Packages
    • Calibrators >
      • Model 714 NO2/NO/O3 Calibration Source
      • Model 306 Ozone Cal Source
    • Product Catalog
  • Data Portal
    • Data Portal V2
  • Downloads
  • Quote
  • Parts Online
  • Contact
  • Distributors
  • Tech Support
  • Options and Custom Builds
  • Calibrations
  • Rentals
  • Videos
  • Our Team
  • R & D
  • Citations
  • Customer Feedback
  • Ozone Decision Tree
  • Ozone Units Converter
  • DewLine™
  • Ozone Generator Calculations
  • 2B Buzz Newsletter
  • News Archive