2B TECHNOLOGIES
  • Home
  • About
  • Applications
    • Ambient Air
    • Ozone Disinfection >
      • Ozone the Destroyer
    • Industrial Ozone
    • Education
    • AQ Sensors
    • Application Notes
  • Products
    • AQSync Air Quality Monitoring Station
    • Ozone >
      • Ambient Ozone Monitors >
        • Model 106-L
        • Model 202 Ozone Monitor
        • Model 205 Ozone Monitor
        • Model 211 Scrubberless Ozone Monitor
        • Model 211-G Ozone Monitor
        • POM, Personal Ozone Monitor
        • Model 306 Ozone Cal Source
      • Industrial Ozone Monitors >
        • Model 106 Series Ozone Monitors
        • Model-106 Series OEM Ozone Monitors
        • Model 106-L
        • Model 106-M
        • Model 106-MH
        • Model 106-H
        • Model 108-L
        • Model UV-106-W Aqueous Ozone Monitor
        • Model 306 Ozone Cal Source
    • NOx >
      • Model 405 nm NOx Monitor
      • Model 714 NO2/NO/O3 Calibration Source
    • Black Carbon
    • Mercury
    • Instrument/Sensor Packages >
      • AQ Sensors vs Instruments
      • Personal Air Monitor (PAM)
      • AQLite Air Monitoring Packages
    • Calibrators >
      • Model 714 NO2/NO/O3 Calibration Source
      • Model 306 Ozone Cal Source
    • Product Catalog
  • Data Portal
    • Data Portal V2
  • Downloads
  • Quote
  • Parts Online
  • Contact
  • Distributors
  • Tech Support
  • Options and Custom Builds
  • Calibrations
  • Rentals
  • Videos
  • Our Team
  • R & D
  • Citations
  • Customer Feedback
  • Ozone Decision Tree
  • Ozone Units Converter
  • DewLine™
  • Ozone Generator Calculations
  • 2B Buzz Newsletter
  • News Archive

Comparison of 2B Tech Ozone Monitors

Which ozone monitor should I purchase?

The following table compares the specifications of the various 2B Tech Ozone Monitors and is meant to be helpful for deciding which Ozone Monitor is best for your application. A discussion of the most appropriate ozone monitors for various applications is given here: Applications  If you have questions or need help with selecting the Ozone Monitor best suited to your needs, please do not hesitate to contact us.
Specification
Model
202
205
106-L
106-M
106-MH
106-H
211 / 211-G
POM
Measurement Principle
UV Absorbance
UV Absorbance
UV Absorbance
UV Absorbance
UV Absorbance
UV Absorbance
UV Absorbance
UV Absorbance
Dual Beam?
Optional Upgrade
Yes
No
No
No
No
Yes
No
Federal Equivalent Method (FEM)
Yes
Yes
Yes
N/A
N/A
N/A
Yes
Yes
Linear Dynamic Range
0-250 ppm
0-250 ppm
0-100 ppm
0-1000 ppm
0-10,000 ppm
0-20 wt%
211: 0-2 ppm
211-G: 0-500 ppb
0-10 ppm
Resolution
0.1 ppb
0.1 ppb
0.1 ppb
0.01 ppm
0.1 ppm
0.01 wt%
0.1 ppb
0.1 ppb
Precision (1σ for 10-s average; aka rms noise)
1.5 ppb  or
2% of Reading
1.0 ppb or
2% of Reading
1.5 ppb or
2% of Reading
0.01 ppm or
2% of Reading
0.05 ppm or
2% of Reading
0.01 wt% or
2% of Reading
0.5 ppb or
1% of Reading
1.5 ppb or
2% of Reading
Accuracy
1.5 ppb  or
2% of Reading
1.0 ppb or
2% of Reading
1.5 ppb or
2% of Reading
0.01 ppm or
2% of Reading
0.05 ppm or
2% of Reading
0.01 wt% or
2% of Reading
211: 1.0 ppb or
1% of Reading
211-G: 1.0 ppb or
2% of Reading
1.5 ppb or
2% of Reading
Calibration
NIST Traceable
NIST Traceable
NIST Traceable
NIST Traceable
NIST Traceable
Iodometric Titration
NIST Traceable
NIST Traceable
Limit of Detection (10-s measurement, 2σ)
3.0 ppb
2.0 ppb
3.0 ppb
0.02 ppm
0.10 ppm
0.02 wt%
1.0 ppb
3.0 ppb
Flow Rate (nominal)
1 L/min
1.8 L/min
1 L/min
1 L/min
1 L/min
Up to 20 L/min
2 L/min
0.8 L/min
Flow Rate Requirement
>0.6 L/min
>1.2 L/min
>0.6 L/min
>0.3 L/min
>0.2 L/min
>0.5 L/min
>1.2 L/min
>0.5 L/min
Baseline Drift
<2 ppb/day
<5 ppb/year
<1 ppb/day
<3 ppb/year
<3 ppb/day
<6 ppb/year
<0.01 ppm/day
<0.03 ppm/year
<0.1ppm/day
<0.3ppm/year
<0.02%/day
<0.05%/month
<1 ppb/day
<3 ppb/year
<2 ppb/day
<5 ppb/year
Sensitivity Drift
<1%/day
<3%/year
<1%/day
<3%/year
<1%/day
<3%/year
<1%/day
<3%/year
<1%/day
<3%/year
<1%/day
<3%/year
<0.5%/day
<3%/year
<1%/day
<3%/year
Measurement Time, Frequency
10 s, 0.1 Hz
2 s, 0.5 Hz
2 s, 0.5 Hz
2 s, 0.5 Hz
2 s, 0.5 Hz
2 s, 0.5 Hz
2 s, 0.5 Hz
10 s, 0.1 Hz
(fast mode: 2s, 0.5 Hz)
Response Time, 100% of Step Change
20 s
2 points
4 s
2 points
4 s
2 points
4 s
2 points
4 s
2 points
4 s
2 points
4 s
2 points
20 s
2 points
(fast mode:
4 s, 2 points)
Averaging Times
1 min, 5 min,
1 hr
10 s,
1 min, 5 min,
1 hr
10 s,
1 min, 5 min,
1 hr
10 s,
1 min, 5 min,
1 hr
10 s,
1 min, 5 min,
1 hr
10 s,
1 min, 5 min,
1 hr
10 s,
1 min, 5 min,
1 hr
1 min, 5 min,
1 hr
Ozone Units
ppb, pphm, ppm, µg m-3,
mg m-3
ppb, pphm, ppm, µg m-3,
mg m-3
ppb, pphm, ppm, µg m-3,
mg m-3
ppb, pphm, ppm, µg m-3,
mg m-3
ppm, mg m-3
vol %, wt % air,
wt % O2, g m-3,
g Nm-3
ppb, pphm, ppm, µg m-3,
mg m-3
ppb
Pressure Units
mbar, torr
mbar, torr
mbar, torr
mbar, torr
mbar, torr
mbar, psi, torr
mbar, torr
torr
Temperature Units
°C, K
°C, K
°C, K
°C, K
°C, K
°C,°F, K
°C, K
K
T and P Corrected
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Operating Temperature Range
0 to 50 °C;
-20 to 50 °C with low T Mods
0 to 50 °C;
-20 to 50 °C with low T Mods
0 to 50 °C
0 to 50 °C
0 to 50 °C
0 to 50 °C
10 to 50 °C
0 to 50 °C
Operating Altitude
~0-13.5 km (0-25 km option)
~0-13.5 km (0-25 km option)
~0-13.5 km (0-25 km option)
~0-5 km
~0-5 km
~0-5 km
~0-13.5 km (0-25 km option)
~0-13.5 km (option for higher altitude modifications)
Power Requirement
100-240 VAC, 50/60 Hz;
11-14 VDC, nominally 600 mA at 12 V;
7.2 watt
100-240 VAC, 50/60 Hz;
11-14 VDC, nominally 650 mA at 12 V;
8 watt
100-240 VAC, 50/60 Hz;
11-28 VDC, nominally 500 mA at 12 V;
6.0 watt
100-240 VAC, 50/60 Hz;
nominally 500 mA at 12 VDC;
6.0 watt
100-240 VAC, 50/60 Hz;
nominally 500 mA at 12 VDC;
6.0 watt
100-240 VAC, 50/60 Hz;
nominally 250 mA at 12 VDC;
3 watt
211: 100-240 VAC, 50/60 Hz;
11-14 VDC, nominally 1 A at 12 V; 12 watt
211-G: 22 watt
100-240 VAC, 50/60 Hz;
7-12 VDC, nominally 250 mA at 12 V;
3 watt
Size
3.7x8.5x11.8 in
9.5x21.5x30 cm
3.7x8.5x11.5 in
9.5x21.5x30 cm
Standard Case:
3.6x7.9x9.4 in
9x20x24 cm
OEM Version:
2.5x7x9 in
6.2x17.8x22.9 cm
Standard Case:
3.6x7.9x9.4 in
9x20x24 cm
OEM Version:
2.5x7x9 in
6.2x17.8x22.9 cm
Standard Case:
3.6x7.9x9.4 in
9x20x24 cm
OEM Version:
2.5x7x9 in
6.2x17.8x22.9 cm
Standard Case:
3.6x7.9x9.4 in
9x20x24 cm
OEM Version:
2.5x7x9 in
6.2x17.8x22.9 cm
17x14.5x5.5 in
43x37x14 cm
5.5x3.0x1.5 in
14.0x7.6x3.8 cm
(with GPS)
4x3x1.5 in 10.2x7.6x3.8 cm
(without GPS)
Weight
5.5 lb
(2.5 kg)

Without instrument case:
2.8 lb (1.3 kg)
5.8 lb
(2.6 kg)

Without instrument case:
3.1 lb (1.4 kg)
Standard Case:
4.2 lb
(1.9 kg)
OEM Version:
2.8 lb
(1.3 kg)
Standard Case:
3.9 lb
(1.8 kg)
OEM Version:
2.5 lb
(1.1 kg)
Standard Case:
3.9 lb
(1.8 kg)
OEM Version:
2.5 lb
(1.1 kg)
Standard Case:
4.8 lb
(2.2 kg)
OEM Version:
3.3 lb
(1.5 kg)
211: 14.7 lb
(6.7 kg)
211-G: 13.4 lb (5.8 kg)
1.0 lb (0.45 kg)

Without battery:
0.8 lb (0.36 kg)
Data Logger Capacity
16,383 lines
16,383 lines
32,736 lines
32,736 lines
32,736 lines
32,736 lines
16,383 lines
8,192 lines
Analog Inputs for Internal Logging of Other Instruments,
0-2.5 V
3 Inputs
3 Inputs
No
No
No
No
No
No
Serial Output, RS232
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
USB Output
Optional External Adapter
Optional External Adapter
Yes
Yes
Yes
Yes
Optional External Adapter
Yes
Flash Card Output
Yes
Yes
No
No
No
No
Yes
No
Data Transfer Baud Rates
2400, 4800, 19200
2400, 4800, 19200
2400, 4800, 19200
2400, 4800, 19200
2400, 4800, 19200
2400, 4800, 19200
2400, 4800, 19200
19200
Analog Voltage Output
0-2.5 V
0-2.5 V
0-2.5 V
0-2.5 V
0-2.5 V
0-2.5 V
0-2.5 V
Option
Analog Current Output
Optional
4-20 mA
Optional
4-20 mA
4-20 mA
4-20 mA
4-20 mA
4-20 mA
Optional
4-20 mA
None
Output Ranges
User-Defined
Scaling Factor in Menu
User-Defined
Scaling Factor in Menu
User-Defined
Scaling Factor in Menu
User-Defined
Scaling Factor in Menu
User-Defined
Scaling Factor in Menu
User-Defined
Scaling Factor in Menu
User-Defined
Scaling Factor in Menu
N/A
DewLine™
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Flow Through
No
No
Option
Option
Option
Yes
No
No
GPS Option
Yes
Yes
No
No
No
No
No
Included
Bluetooth Option
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Relay with 2 Setpoints
No
No
Yes (2)
Yes (2)
Yes (2)
Yes (2)
No
No
Air Pump Lifetime (hours)
20,000
20,000
15,000
15,000
15,000
N/A
15,000
3,000
Flow Meter
Yes
Yes
Yes
Yes
Yes
No
Yes
No
  • Home
  • About
  • Applications
    • Ambient Air
    • Ozone Disinfection >
      • Ozone the Destroyer
    • Industrial Ozone
    • Education
    • AQ Sensors
    • Application Notes
  • Products
    • AQSync Air Quality Monitoring Station
    • Ozone >
      • Ambient Ozone Monitors >
        • Model 106-L
        • Model 202 Ozone Monitor
        • Model 205 Ozone Monitor
        • Model 211 Scrubberless Ozone Monitor
        • Model 211-G Ozone Monitor
        • POM, Personal Ozone Monitor
        • Model 306 Ozone Cal Source
      • Industrial Ozone Monitors >
        • Model 106 Series Ozone Monitors
        • Model-106 Series OEM Ozone Monitors
        • Model 106-L
        • Model 106-M
        • Model 106-MH
        • Model 106-H
        • Model 108-L
        • Model UV-106-W Aqueous Ozone Monitor
        • Model 306 Ozone Cal Source
    • NOx >
      • Model 405 nm NOx Monitor
      • Model 714 NO2/NO/O3 Calibration Source
    • Black Carbon
    • Mercury
    • Instrument/Sensor Packages >
      • AQ Sensors vs Instruments
      • Personal Air Monitor (PAM)
      • AQLite Air Monitoring Packages
    • Calibrators >
      • Model 714 NO2/NO/O3 Calibration Source
      • Model 306 Ozone Cal Source
    • Product Catalog
  • Data Portal
    • Data Portal V2
  • Downloads
  • Quote
  • Parts Online
  • Contact
  • Distributors
  • Tech Support
  • Options and Custom Builds
  • Calibrations
  • Rentals
  • Videos
  • Our Team
  • R & D
  • Citations
  • Customer Feedback
  • Ozone Decision Tree
  • Ozone Units Converter
  • DewLine™
  • Ozone Generator Calculations
  • 2B Buzz Newsletter
  • News Archive